If reversing the door with the unit in normal position, then it is recommended to be two people, otherwise the unit can be placed on its back on the floor. If this method is used the unit must be placed in normal upright position at least two hours before connecting to power. Extension cords terminal block and left bracket is optional. Request a spare parts list
1. Disconnect the power supply
Loosen the two screws in the top panel.
Pull out carefully the top panel.
2. Unscrew the two screws in the lower panel.
3. Remove the cover by using suitable tool and a hammer
4. Remove the lower panel by use of a suitable tool.
Place the lower panel in front of the unit without pulling in the wires
5. Remove the black and red wire from the connector by pressing down the clips.
6. Unscrew the bracket in the top.
NOTE: The door is now loose!
Be careful that the door does not fall!
7. Lift up the door. The wires from the door are pulled up together with the door pin.
Place the door pin in the opposite side of the cabinet.
8. Push the wires from the door down into the door pin and drag them through the door support.
9. Mount the door on the top of the door pin and at the same time draw the wires gently down so that it is not pinched.
Press the door completely down over the door pin!
10. Place the left hinge on the top of the door closer.
Twist the hinge (a quarter turn) in place with a wrench and tighten it with the two screws.
The door is now fixed again.
11. Click the wires to the door light onto the wire retainers and mount them in the connector.
12. Mount the lower panel and top panel.
If the unit has been laid down, it must stand upright for at least 2 hours before reconnecting to power.